-- Network Working Group C. DeSanti
-- Request for Comments: 4983 H.K. Vivek
-- Category: Standards Track K. McCloghrie
-- Cisco Systems
-- S. Gai
-- Nuova Systems
-- August 2007-- Fibre Channel Registered State Change Notification (RSCN) MIB
T11-FC-RSCN-MIB DEFINITIONS::=BEGIN-- The Fibre Channel RSCN MIB
--
-- for the monitoring of registrations by Nx_Ports to receive
-- Registered State Change Notifications (RSCNs), and the
-- monitoring of RSCN usage.
--IMPORTSMODULE-IDENTITY,OBJECT-TYPE,NOTIFICATION-TYPE,Counter32, mib-2 FROM SNMPv2-SMI -- [RFC2578]MODULE-COMPLIANCE,OBJECT-GROUP,NOTIFICATION-GROUPFROM SNMPv2-CONF -- [RFC2580]TruthValueFROM SNMPv2-TC -- [RFC2579]fcmInstanceIndex, fcmSwitchIndex,FcNameIdOrZero,FcAddressIdOrZeroFROM FC-MGMT-MIB -- [RFC4044]
T11NsGs4RejectReasonCodeFROM T11-FC-NAME-SERVER-MIB -- [RFC4438]T11FabricIndexFROM T11-TC-MIB;-- [RFC4439]t11FcRscnMIB MODULE-IDENTITYLAST-UPDATED"200701080000Z"ORGANIZATION"For the initial versions, T11.
For later versions, the IETF's IMSS Working Group."CONTACT-INFO" Claudio DeSanti
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134 USA
EMail: cds@cisco.com
Keith McCloghrie
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134 USA
EMail: kzm@cisco.com"DESCRIPTION"The MIB module for the management of registrations
by Nx_Ports to receive RSCNs (Registered State Change
Notifications) on a Fibre Channel Fabric, as defined
in FC-LS, and for the monitoring of RSCNs sent/received
or rejected in a Fibre Channel Fabric.
Copyright (C) The Internet Society (2007). This version of
this MIB module is part of RFC 4983; see the RFC itself for
full legal notices."REVISION"200701080000Z"DESCRIPTION"Initial version of this MIB module, published as RFC 4983."::={ mib-2 161}t11FcRscnNotifications OBJECTIDENTIFIER::={ t11FcRscnMIB 0}t11FcRscnObjects OBJECTIDENTIFIER::={ t11FcRscnMIB 1}t11FcRscnConformance OBJECTIDENTIFIER::={ t11FcRscnMIB 2}
t11FcRscnRegistrations OBJECTIDENTIFIER::={ t11FcRscnObjects 1}t11FcRscnStats OBJECTIDENTIFIER::={ t11FcRscnObjects 2}t11FcRscnInformation OBJECTIDENTIFIER::={ t11FcRscnObjects 3}-- State Change Registration Tablet11FcRscnRegTable OBJECT-TYPESYNTAXSEQUENCEOF T11FcRscnRegEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table of Nx_Ports that have registered to receive
RSCNs on all Fabrics configured on one or more Fibre
Channel switches."::={ t11FcRscnRegistrations 1}t11FcRscnRegEntry OBJECT-TYPESYNTAX T11FcRscnRegEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry containing information about one Nx_Port that
has registered with a particular switch (identified by
values of fcmInstanceIndex and fcmSwitchIndex) for a
particular Fabric (identified by a t11FcRscnFabricIndex
value)."INDEX{ fcmInstanceIndex, fcmSwitchIndex, t11FcRscnFabricIndex,
t11FcRscnRegFcId }::={ t11FcRscnRegTable 1}
T11FcRscnRegEntry ::=SEQUENCE{
t11FcRscnFabricIndex T11FabricIndex,
t11FcRscnRegFcId FcAddressIdOrZero,
t11FcRscnRegType BITS}t11FcRscnFabricIndex OBJECT-TYPESYNTAXT11FabricIndexMAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An index value that uniquely identifies a particular
Fabric.
In a Fabric conformant to FC-SW-4, multiple Virtual Fabrics
can operate within one (or more) physical infrastructures.
In such a case, this index value is used to uniquely
identify a particular Fabric within a physical
infrastructure.
In a Fabric that has (or can have) only a single Fabric
operating within the physical infrastructure, the
value of this Fabric Index will always be 1."REFERENCE"ANSI INCITS 418-2006, Fibre Channel - Switch Fabric - 4
(FC-SW-4), December 2006."
::={ t11FcRscnRegEntry 1}t11FcRscnRegFcId OBJECT-TYPESYNTAXFcAddressIdOrZero(SIZE(3))MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The Fibre Channel Address Identifier of the
registering Nx_Port."::={ t11FcRscnRegEntry 2}t11FcRscnRegType OBJECT-TYPESYNTAXBITS{fromFabricController(0),fromNxPort(1)}MAX-ACCESSread-only
STATUScurrentDESCRIPTION"This object indicates the type of registration
desired by the registering Nx_Port, one bit per type:
'fromFabricController' -- RSCNs generated for events
detected by the Fabric Controller.
'fromNxPorts' -- RSCNs generated for events
detected by the affected Nx_Port."REFERENCE"ANSI INCITS 433-2007, Fibre Channel - Link Services
(FC-LS), July 2007, Table 40."::={ t11FcRscnRegEntry 3}-- Statisticst11FcRscnStatsTable OBJECT-TYPESYNTAXSEQUENCEOF T11FcRscnStatsEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The RSCN-related statistics on all Fabrics configured
on one or more Fibre Channel switches.
Two levels of statistics are included:
1) counters at the message-type level, for:
- the number of SCRs received/rejected,
- the number of RSCNs sent/received/rejected,
- the number of SW_RSCNs sent/received/rejected.
2) counters of sent/received RSCNs per 'Event
Qualifier' value. Note that if and when several
RSCN events are coalesced into a single RSCN
message, then that message may be counted in
more than one of these counters."::={ t11FcRscnStats 1}t11FcRscnStatsEntry OBJECT-TYPESYNTAX T11FcRscnStatsEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry containing statistics for a particular Fabric
(identified by a t11FcRscnFabricIndex value) on a particular
switch (identified by values of fcmInstanceIndex and
fcmSwitchIndex)."INDEX{ fcmInstanceIndex, fcmSwitchIndex, t11FcRscnFabricIndex }::={ t11FcRscnStatsTable 1}
T11FcRscnStatsEntry ::=SEQUENCE{
t11FcRscnInScrs Counter32,
t11FcRscnInRscns Counter32,
t11FcRscnOutRscns Counter32,
t11FcRscnInSwRscns Counter32,
t11FcRscnOutSwRscns Counter32,
t11FcRscnScrRejects Counter32,
t11FcRscnRscnRejects Counter32,
t11FcRscnSwRscnRejects Counter32,
t11FcRscnInUnspecifiedRscns Counter32,
t11FcRscnOutUnspecifiedRscns Counter32,
t11FcRscnInChangedAttribRscns Counter32,
t11FcRscnOutChangedAttribRscns Counter32,
t11FcRscnInChangedServiceRscns Counter32,
t11FcRscnOutChangedServiceRscns Counter32,
t11FcRscnInChangedSwitchRscns Counter32,
t11FcRscnOutChangedSwitchRscns Counter32,
t11FcRscnInRemovedRscns Counter32,
t11FcRscnOutRemovedRscns Counter32}t11FcRscnInScrs OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of SCRs received from Nx_Ports
by this switch on this Fabric.
This counter has no discontinuities other than
those that all Counter32s have when sysUpTime=0."::={ t11FcRscnStatsEntry 1}t11FcRscnInRscns OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of RSCNs received from Nx_Ports
by this switch on this Fabric.
This counter has no discontinuities other than
those that all Counter32s have when sysUpTime=0."::={ t11FcRscnStatsEntry 2}t11FcRscnOutRscns OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of RSCNs transmitted to Nx_Ports
by this switch on this Fabric.
This counter has no discontinuities other than
those that all Counter32s have when sysUpTime=0."::={ t11FcRscnStatsEntry 3}t11FcRscnInSwRscns OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of SW_RSCNs received by this switch from
other switches on this Fabric.
This counter has no discontinuities other than
those that all Counter32s have when sysUpTime=0."::={ t11FcRscnStatsEntry 4}t11FcRscnOutSwRscns OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrent
DESCRIPTION"The number of SW_RSCNs transmitted by this switch
from other switches on this Fabric.
This counter has no discontinuities other than
those that all Counter32s have when sysUpTime=0."::={ t11FcRscnStatsEntry 5}t11FcRscnScrRejects OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of SCRs rejected by this switch on
this Fabric.
This counter has no discontinuities other than
those that all Counter32s have when sysUpTime=0."::={ t11FcRscnStatsEntry 6}t11FcRscnRscnRejects OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-only
STATUScurrentDESCRIPTION"The number of RSCNs rejected by this switch on this
Fabric.
This counter has no discontinuities other than
those that all Counter32s have when sysUpTime=0."::={ t11FcRscnStatsEntry 7}t11FcRscnSwRscnRejects OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of SW_RSCN rejected by this switch on this
Fabric.
This counter has no discontinuities other than
those that all Counter32s have when sysUpTime=0."::={ t11FcRscnStatsEntry 8}t11FcRscnInUnspecifiedRscns OBJECT-TYPESYNTAXCounter32
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of Registered State Change Notifications
(RSCNs) received by this switch on this Fabric which
contained an RSCN Event Qualifier value of '0000'b
meaning 'Event is not specified'.
This counter has no discontinuities other than
those that all Counter32s have when sysUpTime=0."REFERENCE"ANSI INCITS 433-2007, Fibre Channel - Link Services
(FC-LS), July 2007, Table 36."::={ t11FcRscnStatsEntry 9}t11FcRscnOutUnspecifiedRscns OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of Registered State Change Notifications
(RSCNs) sent by this switch on this Fabric which
contained an RSCN Event Qualifier value of '0000'b
meaning 'Event is not specified'.
This counter has no discontinuities other than
those that all Counter32s have when sysUpTime=0."REFERENCE"ANSI INCITS 433-2007, Fibre Channel - Link Services
(FC-LS), July 2007, Table 36."::={ t11FcRscnStatsEntry 10}t11FcRscnInChangedAttribRscns OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of Registered State Change Notifications
(RSCNs) received by this switch on this Fabric which
contained an RSCN Event Qualifier value of '0002'b
meaning 'Changed Port Attribute'.
This counter has no discontinuities other than
those that all Counter32s have when sysUpTime=0."REFERENCE
"ANSI INCITS 433-2007, Fibre Channel - Link Services
(FC-LS), July 2007, Table 36."::={ t11FcRscnStatsEntry 11}t11FcRscnOutChangedAttribRscns OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of Registered State Change Notifications
(RSCNs) sent by this switch on this Fabric which
contained an RSCN Event Qualifier value of '0002'b
meaning 'Changed Port Attribute'.
This counter has no discontinuities other than
those that all Counter32s have when sysUpTime=0."REFERENCE"ANSI INCITS 433-2007, Fibre Channel - Link Services
(FC-LS), July 2007, Table 36."::={ t11FcRscnStatsEntry 12}t11FcRscnInChangedServiceRscns OBJECT-TYPE
SYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of Registered State Change Notifications
(RSCNs) received by this switch on this Fabric which
contained an RSCN Event Qualifier value of '0003'b
meaning 'Changed Service Object'.
This counter has no discontinuities other than
those that all Counter32s have when sysUpTime=0."REFERENCE"ANSI INCITS 433-2007, Fibre Channel - Link Services
(FC-LS), July 2007, Table 36."::={ t11FcRscnStatsEntry 13}t11FcRscnOutChangedServiceRscns OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION
"The number of Registered State Change Notifications
(RSCNs) sent by this switch on this Fabric which
contained an RSCN Event Qualifier value of '0003'b
meaning 'Changed Service Object'.
This counter has no discontinuities other than
those that all Counter32s have when sysUpTime=0."REFERENCE"ANSI INCITS 433-2007, Fibre Channel - Link Services
(FC-LS), July 2007, Table 36."::={ t11FcRscnStatsEntry 14}t11FcRscnInChangedSwitchRscns OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of Registered State Change Notifications
(RSCNs) received by this switch on this Fabric which
contained an RSCN Event Qualifier value of '0004'b
meaning 'Changed Switch Configuration'.
This counter has no discontinuities other than
those that all Counter32s have when sysUpTime=0."REFERENCE"ANSI INCITS 433-2007, Fibre Channel - Link Services
(FC-LS), July 2007, Table 36."::={ t11FcRscnStatsEntry 15}t11FcRscnOutChangedSwitchRscns OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of Registered State Change Notifications
(RSCNs) sent by this switch on this Fabric which
contained an RSCN Event Qualifier value of '0004'b
meaning 'Changed Switch Configuration'.
This counter has no discontinuities other than
those that all Counter32s have when sysUpTime=0."REFERENCE"ANSI INCITS 433-2007, Fibre Channel - Link Services
(FC-LS), July 2007, Table 36."::={ t11FcRscnStatsEntry 16}
t11FcRscnInRemovedRscns OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of Registered State Change Notifications
(RSCNs) received by this switch on this Fabric which
contained an RSCN Event Qualifier value of '0005'b
meaning 'Removed Object'.
This counter has no discontinuities other than
those that all Counter32s have when sysUpTime=0."REFERENCE"ANSI INCITS 433-2007, Fibre Channel - Link Services
(FC-LS), July 2007, Table 36."::={ t11FcRscnStatsEntry 17}t11FcRscnOutRemovedRscns OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrent
DESCRIPTION"The number of Registered State Change Notifications
(RSCNs) sent by this switch on this Fabric which
contained an RSCN Event Qualifier value of '0005'b
meaning 'Removed Object'.
This counter has no discontinuities other than
those that all Counter32s have when sysUpTime=0."REFERENCE"ANSI INCITS 433-2007, Fibre Channel - Link Services
(FC-LS), July 2007, Table 36."::={ t11FcRscnStatsEntry 18}--
-- Notification Control Table
--t11FcRscnNotifyControlTable OBJECT-TYPESYNTAXSEQUENCEOF T11FcRscnNotifyControlEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table of control information for notifications
generated due to the rejection of an SCR or RSCN."
::={ t11FcRscnInformation 1}t11FcRscnNotifyControlEntry OBJECT-TYPESYNTAX T11FcRscnNotifyControlEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Each entry contains notification control information
concerning the rejection of RSCN/SCRs for a particular
Fabric (identified by the value of t11FcRscnFabricIndex)
by a particular switch (identified by values of
fcmInstanceIndex and fcmSwitchIndex)."INDEX{ fcmInstanceIndex, fcmSwitchIndex, t11FcRscnFabricIndex }::={ t11FcRscnNotifyControlTable 1}
T11FcRscnNotifyControlEntry ::=SEQUENCE{
t11FcRscnIlsRejectNotifyEnable TruthValue,
t11FcRscnElsRejectNotifyEnable TruthValue,
t11FcRscnRejectedRequestString OCTETSTRING,
t11FcRscnRejectedRequestSource FcNameIdOrZero,
t11FcRscnRejectReasonCode T11NsGs4RejectReasonCode,
t11FcRscnRejectReasonCodeExp OCTETSTRING,
t11FcRscnRejectReasonVendorCode OCTETSTRING}t11FcRscnIlsRejectNotifyEnable OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-writeSTATUScurrentDESCRIPTION"This object specifies if a t11FcRscnIlsRejectReqNotify
notification should be generated when this switch
rejects an SW_RSCN on this Fabric.
Values written to this object should be retained
over agent reboots."DEFVAL{ false }::={ t11FcRscnNotifyControlEntry 1}t11FcRscnElsRejectNotifyEnable OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-writeSTATUScurrentDESCRIPTION"This object specifies if a t11FcRscnElsRejectReqNotify
notification should be generated when this switch
rejects an RSCN or SCR on this Fabric.
Values written to this object should be retained
over agent reboots."DEFVAL{ false }::={ t11FcRscnNotifyControlEntry 2}t11FcRscnRejectedRequestString OBJECT-TYPESYNTAXOCTETSTRING(SIZE(0..255))
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The binary content of the RSCN, SCR, or SW_RSCN that
was most recently rejected by this switch on this Fabric.
The value is formatted as an octet string (in network
byte order) as described in the relevant Fibre Channel
standard, containing the payload (which is typically a
list of affected ports and error codes) of the rejected
RSCN or SCR as described in FC-LS, or the rejected
SW_RSCN as described in FC-SW-4.
This object contains the zero-length string if and when
the RSCN/SCR/SW_RSCN payload is unavailable. When the
length of this object is 255 octets, it contains the
first 255 octets of the payload (in network byte order)."REFERENCE"ANSI INCITS 433-2007, Fibre Channel - Link Services
(FC-LS), July 2007, Tables 34 & 39.
ANSI INCITS 418-2006, Fibre Channel - Switch Fabric - 4
(FC-SW-4), December 2006, Table 45."::={ t11FcRscnNotifyControlEntry 3}t11FcRscnRejectedRequestSource OBJECT-TYPESYNTAXFcNameIdOrZeroMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The WWN that was the source of the RSCN, SCR, or
SW_RSCN that was most recently rejected by this switch
on this Fabric."::={ t11FcRscnNotifyControlEntry 4}t11FcRscnRejectReasonCode OBJECT-TYPESYNTAXT11NsGs4RejectReasonCodeMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This object contains the Reason Code of the most recent
rejection by this switch of an RSCN, SCR or SW_RSCN on
this Fabric."REFERENCE"ANSI INCITS 433-2007, Fibre Channel - Link Services
(FC-LS), July 2007, Table 146.
ANSI INCITS 418-2006, Fibre Channel - Switch Fabric - 4
(FC-SW-4), December 2006, Table 5."::={ t11FcRscnNotifyControlEntry 5}t11FcRscnRejectReasonCodeExp OBJECT-TYPESYNTAXOCTETSTRING(SIZE(1))MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This object contains the Reason Code Explanation
of the most recent rejection by this switch of an
RSCN, SCR or SW_RSCN on this Fabric."REFERENCE"ANSI INCITS 433-2007, Fibre Channel - Link Services
(FC-LS), July 2007, Table 147.
ANSI INCITS 418-2006, Fibre Channel - Switch Fabric - 4
(FC-SW-4), December 2006, Table 6."::={ t11FcRscnNotifyControlEntry 6}t11FcRscnRejectReasonVendorCode OBJECT-TYPESYNTAXOCTETSTRING(SIZE(1))MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This object contains the Reason Vendor Specific
Code of the most recent rejection by this switch
of an RSCN, SCR or SW_RSCN on this Fabric."REFERENCE"ANSI INCITS 433-2007, Fibre Channel - Link Services
(FC-LS), July 2007, Table 148.
ANSI INCITS 418-2006, Fibre Channel - Switch Fabric - 4
(FC-SW-4), December 2006, Section 6.1.3."
::={ t11FcRscnNotifyControlEntry 7}-- Notificationst11FcRscnElsRejectReqNotify NOTIFICATION-TYPEOBJECTS{ t11FcRscnRejectedRequestString,
t11FcRscnRejectedRequestSource,
t11FcRscnRejectReasonCode,
t11FcRscnRejectReasonCodeExp,
t11FcRscnRejectReasonVendorCode }STATUScurrentDESCRIPTION"This notification is generated when a switch rejects
an SCR or RSCN.
The value of t11FcRscnRejectedRequestString indicates the
binary content of the rejected request if available, or
the zero-length string otherwise. The source of the
rejected request is given by t11FcRscnRejectedRequestSource,
and the reason for rejection is given by the values of
t11FcRscnRejectReasonCode, t11FcRscnRejectReasonCodeExp
and t11FcRscnRejectReasonVendorCode."::={ t11FcRscnNotifications 1}t11FcRscnIlsRejectReqNotify NOTIFICATION-TYPEOBJECTS{ t11FcRscnRejectedRequestString,
t11FcRscnRejectedRequestSource,
t11FcRscnRejectReasonCode,
t11FcRscnRejectReasonCodeExp,
t11FcRscnRejectReasonVendorCode }STATUScurrentDESCRIPTION"This notification is generated when a switch rejects
an SW_RSCN.
The value of t11FcRscnRejectedRequestString indicates the
binary content of the rejected request if available, or
the zero-length string otherwise. The source of the
rejected request is given by t11FcRscnRejectedRequestSource,
and the reason for rejection is given by the values of
t11FcRscnRejectReasonCode, t11FcRscnRejectReasonCodeExp
and t11FcRscnRejectReasonVendorCode."
::={ t11FcRscnNotifications 2}-- Conformancet11FcRscnCompliances OBJECTIDENTIFIER::={ t11FcRscnConformance 1}t11FcRscnGroups OBJECTIDENTIFIER::={ t11FcRscnConformance 2}t11FcRscnCompliance MODULE-COMPLIANCESTATUScurrentDESCRIPTION"The compliance statement for entities that implement
this MIB."MODULEMANDATORY-GROUPS{ t11FcRscnRegistrationGroup,
t11FcRscnNotifyControlGroup,
t11FcRscnNotifyGroup }GROUP t11FcRscnStatsGroup
DESCRIPTION"These counters, containing RSCN-related statistics, are
mandatory only for those systems that count such events."OBJECT t11FcRscnIlsRejectNotifyEnable
MIN-ACCESSread-onlyDESCRIPTION"Write access is not required."OBJECT t11FcRscnElsRejectNotifyEnable
MIN-ACCESSread-onlyDESCRIPTION"Write access is not required."::={ t11FcRscnCompliances 1}-- Units of conformancet11FcRscnRegistrationGroup OBJECT-GROUPOBJECTS{ t11FcRscnRegType }STATUScurrentDESCRIPTION"A collection of objects for monitoring RSCN
registrations."::={ t11FcRscnGroups 1}
t11FcRscnStatsGroup OBJECT-GROUPOBJECTS{ t11FcRscnInScrs,
t11FcRscnInRscns,
t11FcRscnOutRscns,
t11FcRscnInSwRscns,
t11FcRscnOutSwRscns,
t11FcRscnScrRejects,
t11FcRscnRscnRejects,
t11FcRscnSwRscnRejects,
t11FcRscnInUnspecifiedRscns,
t11FcRscnOutUnspecifiedRscns,
t11FcRscnInChangedAttribRscns,
t11FcRscnOutChangedAttribRscns,
t11FcRscnInChangedServiceRscns,
t11FcRscnOutChangedServiceRscns,
t11FcRscnInChangedSwitchRscns,
t11FcRscnOutChangedSwitchRscns,
t11FcRscnInRemovedRscns,
t11FcRscnOutRemovedRscns
}STATUScurrentDESCRIPTION"A collection of objects for collecting RSCN-related
statistics."::={ t11FcRscnGroups 2}t11FcRscnNotifyControlGroup OBJECT-GROUPOBJECTS{ t11FcRscnIlsRejectNotifyEnable,
t11FcRscnElsRejectNotifyEnable,
t11FcRscnRejectedRequestString,
t11FcRscnRejectedRequestSource,
t11FcRscnRejectReasonCode,
t11FcRscnRejectReasonCodeExp,
t11FcRscnRejectReasonVendorCode
}STATUScurrentDESCRIPTION"A collection of notification control and
notification information objects."::={ t11FcRscnGroups 3}
t11FcRscnNotifyGroup NOTIFICATION-GROUPNOTIFICATIONS{ t11FcRscnIlsRejectReqNotify,
t11FcRscnElsRejectReqNotify
}STATUScurrentDESCRIPTION"A collection of notifications for monitoring
ILS and ELS rejections by the RSCN module."::={ t11FcRscnGroups 4}END